| Nominal wattage | 50.00 W |
| Nominal output power | 50 W 1) |
| Nominal voltage | 220…240 V |
| Nominal output voltage | 24 V 2) |
| Input voltage range | 220…240 V |
| Input voltage AC | 198…264 V 3) |
| U-OUT (working voltage) | 24 V |
| Type of current | DC |
| Nominal current | 400 mA |
| Inrush current | 25.2 A |
| Output ripple current (100 Hz) | 5 % |
| Mains frequency | 50…60 Hz |
| Total harmonic distortion | < 10 % 4) |
| Power factor λ | ≥0.96 5) |
| ECG efficiency | 87 % 6) |
| Max. ECG no. on circuit breaker 10 A (B) | 14 |
| Max. ECG no. on circuit breaker 16 A (B) | 23 |
| Max. ECG no. on circuit breaker 25 A (B) | 36 |
| Max. ECG no. on circuit breaker 10 A (C) | 20 |
| Max. ECG no. on circuit breaker 16 A (C) | 32 |
| Surge capability (L/N-Ground) | 4 kV |
| Surge capability (L-N) | 6 kV |
| Galvanic isolation | SELV |
| Stroboscope effect metric (SVM) | < 0.4 |
| Length | 127.00 mm |
| Mounting hole spacing, length | 117 mm |
| Width | 39.00 mm |
| Height | 28.00 mm |
| Cable cross-section, input side | 3*1.0 mm² |
| Cable cross-section, output side | 2*1.0 mm² |
| Prewired | Yes |
| Product weight | 260.00 g |
| Product color | Aluminum |
| Casing material | Metal |
| Body material | Metal |
| Ambient temperature range | -40…+55 °C |
| Maximum temperature at tc test point | 90 °C |
| Max.housing temperature in case of fault | 110 °C |
| Temperature range in operation | -40…+55 °C |
| Permitted rel. humidity during operation | 20…90 % 1) |
| ECG lifetime | 50000 h 1) |
| Number of switching cycles | 100000 |
| Encapsulated | Yes |
| Product remark | Available from September 2026 |
| Dimmable | No |
| Dimming interface | Not dimmable |
| Overheating protection | No |
| Overload protection | No |
| Short-circuit protection | Yes |
| Suitable for fixtures with prot. class | I |
| Suitable for emergency lighting | No |
| Type of connection, output side | Cables |
| Approval marks – approval | CE; UKCA; EAC; ENEC |
| Standards | Acc. to EN 61347-1; Acc. to EN 61347-2-13; Acc. to EN 55015; Acc. to EN 61547; Acc. to EN 61000-3-2; Acc. to EN 62384 |
| Protection class | I |
| Type of protection | IP67 |
| Temperature range at storage | -40…+85 °C |
| Minimum rate of recycled material in packaging | 80 % 1) |
| Minimum percentage of recycled content in the product | 0 % 1) |
| Product recyclability | Mostly recyclable product 1) |
| Packaging recyclability | Mostly recyclable packaging 1) |
| List of dangerous substances contained in the product in concentrations greater than 0.1% in mass percentage | No |
| Contains substances of very high concern in concentrations greater than 0.1% by mass percentage | No |
| Product code | Packaging unit (Pieces/Unit) | Dimensions (length x width x height) | Gross weight | Volume |
|---|---|---|---|---|
| 4099854877780 | Folding box 1 |
167 mm x 66 mm x 38 mm | 280.00 g | 0.42 dm³ |
| 4099854877797 | Shipping box 10 |
335 mm x 180 mm x 108 mm | 3010.00 g | 6.51 dm³ |